Critiquing Time-of-Use pricing in Ontario

机译:评估安大略省的使用时间定价

获取原文

摘要

Since 2006, with the progressive deployment of Advanced Metering Infrastructure, jurisdictions in the Canadian province of Ontario have been increasingly using Time-Of-Use (TOU) pricing with the objective of reducing the mean peak-to-average load ratio and thus excess generation capacity. We analyse the hourly aggregate load data to study whether the choice of TOU parameters (i.e., number of seasons, season start and end times, and choice of peak and off-peak times) adequately reflects the aggregate load, and to study whether TOU pricing has actually resulted in a decrease in the mean peak-to-average ratio. We find that since the introduction of TOU pricing, not only has the mean peak-to-average load ratio actually increased but also that the currently implemented TOU parameters are far from optimal. Based on our findings, we make concrete recommendations to improve the TOU pricing scheme in Ontario.
机译:自2006年以来,随着先进计量基础设施的逐步部署,加拿大安大略省的司法管辖区越来越多地使用使用时间(TOU)定价,其目的是降低平均峰值平均负荷比,从而超出容量。我们分析了每小时的总载荷数据来研究TOU参数的选择(即,季节,季节开始和结束时间,以及峰值和非高峰时间的选择)充分地反映了骨料负荷,并研究是否定价实际上导致平均峰平均比率降低。我们发现,自引入TOU定价以来,不仅具有平均峰值平均负荷比率实际上增加,而且目前实施的TOU参数远非最佳。根据我们的调查结果,我们制定具体的建议,以改善安大略省的TOU定价计划。