首页> 外文会议>IEEE International Electric Machines and Drives Conference >Safety Operation Area of Zero-Crossing Detection based Sensorless High Speed BLDC Motor Drives
【24h】

Safety Operation Area of Zero-Crossing Detection based Sensorless High Speed BLDC Motor Drives

机译:基于零交叉检测的无传感器高速BLDC电机驱动器的安全操作区域

获取原文

摘要

For zero-crossing detection based sensorless BLDC drives, long commutation freewheeling duration will increase the difficulty of zero-crossing detection and limit the sensorless safety operation area. In extreme cases, zero crossing of back EMF will not be discernable when the commutation freewheeling duration exceeds 30°, causing the failure of sensorless drives. In this paper, the relation between the commutation freewheeling path and the PWM switching pattern is described. Besides, an iteration method for determining the safety operation area is presented. It demonstrates that a suitable PWM switching pattern can reduce the freewheeling angle and broaden the sensorless safety operation area.
机译:对于基于零交叉检测的无传感器BLDC驱动器,较长的换向续流持续时间将增加零交叉检测的难度并限制无传感器安全操作区域。在极端情况下,当换向续流持续时间超过30时,将无法识别反电动势的零交叉。 ° ,导致无传感器驱动器发生故障。本文描述了换向续流路径与PWM开关模式之间的关系。此外,提出了一种确定安全操作区域的迭代方法。结果表明,合适的PWM开关模式可以减小续流角并扩大无传感器安全操作区域。