首页> 外文会议>Antenna Measurement Techniques Association Symposium >Surface and Internal Temperature versus Incident Field Measurements of Polyurethane Based Absorbers in the Ku Band
【24h】

Surface and Internal Temperature versus Incident Field Measurements of Polyurethane Based Absorbers in the Ku Band

机译:在KU带中的聚氨酯基吸收剂的表面和内部温度与事件场测量

获取原文

摘要

In recent years there has been an increased need for testing antennas and radar systems at high power. Since absorbers work by transforming electromagnetic energy into thermal energy there is a danger that in the presence of high fields the absorber will reach temperatures that will cause it to ignite. In the present paper standard polyurethane absorber is illuminated by a conical horn antenna. Different field levels are used to illuminate the sample. The internal and surface temperature of the sample is measured. From these measurements a behavior of the temperature versus field can be determined. Absorbers with and without a rubberized surface coating are also investigated to study their thermal behavior. This becomes very useful in determining if higher power materials may be required for testing active arrays or radar systems. The effects of lowering the temperature of the absorber by using airflow across the tips are also studied.
机译:近年来,在高功率下测试天线和雷达系统已经增加了需求。由于吸收剂通过将电磁能转化为热能,因此存在在高领域存在的危险,吸收器会达到将导致它点燃的温度。在本文中,标准的聚氨酯吸收器由锥形喇叭天线照射。不同的场级别用于照亮样品。测量样品的内部和表面温度。从这些测量,可以确定温度与场的行为。还研究了具有且没有橡胶表面涂层的吸收剂,以研究其热行为。这在确定可能需要更高的功率材料时可能是非常有用的,以测试有源阵列或雷达系统。还研究了通过在尖端上使用气流降低吸收器温度的影响。