首页> 外文会议>Air and Waste Management Association annual conference and exhibition >Groundwater Modeling for Closure of the Little Blue Run CCR Disposal Area
【24h】

Groundwater Modeling for Closure of the Little Blue Run CCR Disposal Area

机译:小蓝径CCR处理区封闭的地下水模拟

获取原文

摘要

The Little Blue Run (LBR) disposal area is a 900+ acre impoundment that has been used since 1975 for the disposal of coal combustion residuals (CCR) from FirstEnergy's Bruce Mansfield Generating Station. The disposal area consists of an unlined valley fill impoundment supported by an earth and rock fill dam. The CCR materials in LBR consist of calcium sulfite scrubber material, granulated blast furnace slag, lime, and fly ash that have been hydraulically placed. A digital groundwater model was prepared for the facility to compare closure alternatives and to evaluate environmental implications of the facility after closure. The model consisted of nine layers and over 140,000 cells. It was constructed and calibrated to match observed aquifer conditions and groundwater levels within and surrounding LBR. As part of the selected long-term closure program, the CCR impoundment will be capped with a geosynthetic liner and soil cover. An anticipated result of closure is a significant drop in the water level, and subsequent settlement, within the CCR material inside the impoundment. Recognizing that significant settlement could impact the surface drainage and final cover system following closure, the groundwater model was used to predict post closure groundwater levels. A long-term simulation was run to predict the water table drawdown 50 years after the final cover system will be placed. The simulated timeline included ongoing disposal, potential site closure options, and cap system placement. The post-closure water level is predicted to drop more than 100 feet with the maximum amount occurring where the CCR deposits are the thickest. The reduction in water levels appears to be greatly dependent on the aerial extent of standing water on top of the impoundment. The majority of water drawdown within the CCR occurs within the first 24 years after closure. This analysis assisted in the selection of the final closure design for LBR.
机译:Little Blue Run(LBR)处置区是一个900英亩以上的蓄水池,自1975年以来一直用于处置FirstEnergy的Bruce Mansfield发电站的燃煤残渣(CCR)。弃置区由无衬砌的谷底蓄水库组成,并由土石坝支撑。 LBR中的CCR材料由水力放置的亚硫酸钙洗涤器材料,高炉矿渣粉,石灰和粉煤灰组成。为该设施准备了一个数字地下水模型,以比较关闭方案,并评估关闭后设施对环境的影响。该模型由九层和超过140,000个单元组成。它的构造和校准使其与LBR内外的含水层条件和地下水位相匹配。作为选定的长期封闭计划的一部分,将用土工合成材料衬里和土壤覆盖物封盖CCR蓄水层。封闭的预期结果是蓄水池内CCR材料内的水位明显下降,并随后沉降。认识到大量的沉降会影响封闭后的地表排水和最终覆盖系统,因此使用地下水模型来预测封闭后的地下水位。进行了长期模拟,以预测最终的覆盖系统放置50年后的地下水位下降情况。模拟的时间表包括进行中的处置,潜在的站点关闭选项和封顶系统放置。预计关闭后的水位将下降100英尺以上,其中CCR沉积物最厚的地方出现的水量最大。水位的降低似乎很大程度上取决于蓄水池顶部积水的空中范围。 CCR内的大部分取水发生在关闭后的头24年内。该分析有助于选择LBR的最终密封设计。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号