The Little Blue Run (LBR) disposal area is a 900+ acre impoundment that has been used since 1975 for the disposal of coal combustion residuals (CCR) from FirstEnergy's Bruce Mansfield Generating Station. The disposal area consists of an unlined valley fill impoundment supported by an earth and rock fill dam. The CCR materials in LBR consist of calcium sulfite scrubber material, granulated blast furnace slag, lime, and fly ash that have been hydraulically placed. A digital groundwater model was prepared for the facility to compare closure alternatives and to evaluate environmental implications of the facility after closure. The model consisted of nine layers and over 140,000 cells. It was constructed and calibrated to match observed aquifer conditions and groundwater levels within and surrounding LBR. As part of the selected long-term closure program, the CCR impoundment will be capped with a geosynthetic liner and soil cover. An anticipated result of closure is a significant drop in the water level, and subsequent settlement, within the CCR material inside the impoundment. Recognizing that significant settlement could impact the surface drainage and final cover system following closure, the groundwater model was used to predict post closure groundwater levels. A long-term simulation was run to predict the water table drawdown 50 years after the final cover system will be placed. The simulated timeline included ongoing disposal, potential site closure options, and cap system placement. The post-closure water level is predicted to drop more than 100 feet with the maximum amount occurring where the CCR deposits are the thickest. The reduction in water levels appears to be greatly dependent on the aerial extent of standing water on top of the impoundment. The majority of water drawdown within the CCR occurs within the first 24 years after closure. This analysis assisted in the selection of the final closure design for LBR.
机译:Little Blue Run(LBR)处置区域是900+英亩的蓄水区,自1975年以来已使用,用于从Firstenergy布鲁斯曼斯菲尔德发电站处理煤炭燃烧残留物(CCR)。处置区由地球和岩石填充大坝支持的无衬里填充蓄水池组成。 LBR中的CCR材料由硫酸钙洗涤材料,粒状高炉炉渣,石灰和粉煤灰组成,液压放置。为该设施准备了一种数字地下水模型来比较闭合替代品并在关闭后评估设施的环境含义。该模型由九层和超过140,000个细胞组成。它被构建和校准,以匹配观察到的含水层和地下水位和周围的LBR。作为所选长期封闭程序的一部分,CCR蓄积将用土工合成衬垫和土壤覆盖盖。在蓄水池内的CCR材料内,闭合的预期结果是水位的显着下降和随后的沉降。认识到显着的沉降可能会影响闭合后表面排水和最终覆盖系统,地下水模型用于预测后闭合地下水位。运行长期仿真以预测50年后的水位绘制,在最终覆盖系统将放置后。模拟时间轴包括持续处置,潜在的网站闭合选项和CAP系统放置。后闭后水位预计将超过100英尺,最大量发生在CCR沉积物是最厚的。水平的减少似乎大大依赖于蓄水池顶部的常设水的空中程度。 CCR内的大多数水缩减情况发生在封闭后的前24岁内。该分析辅助选择LBR的最终闭合设计。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号