首页> 外文会议>IEEE/PES Transmission and Distribution Conference and Exposition >Comparison of diagnostic method for the pattern analysis due to artificial defects introduced at the interface in XLPE cable joint using laboratory model
【24h】

Comparison of diagnostic method for the pattern analysis due to artificial defects introduced at the interface in XLPE cable joint using laboratory model

机译:实验室模型XLPE电缆关节界面诊断方法对图案分析的诊断方法

获取原文

摘要

In this work, in order to realize the possible defects at the cable joint interface, four different types of artificial defects are provided such as conducting, insulating substances, void and scratches. And the analysis related to the PD patterns has been performed by means of Phase Resolved Partial Discharge Analysis (PRPDA) and Chaotic Analysis of Partial Discharge (CAPD) as well. The latter has been proposed by our previous communication. As results, it could be pointed out that each defect has shown particular characteristics in its pattern respectively and that the nature of defect causing partial discharge could be identified more distinctively when the CAPD is combined with conventional statistic method, PRPDA.
机译:在这项工作中,为了实现电缆接头接口的可能缺陷,提供了四种不同类型的人工缺陷,例如导电,绝缘物质,空隙和划痕。并且通过相位分辨的局部放电分析(PRPDA)和局部放电(CAPD)的混沌分析已经进行了与PD图案相关的分析。后者已通过我们之前的沟通提出。结果,可以指出,当CAPD与常规统计方法结合PRPDA时,每个缺陷分别示出了其图案中的特定特性,并且可以更明显地识别出导致偏放电的缺陷的性质。