首页> 外文会议>Conference on computer-aided diagnosis >Quantification, Validation, and Follow-up of Small Bowel Motility in Crohn's Disease
【24h】

Quantification, Validation, and Follow-up of Small Bowel Motility in Crohn's Disease

机译:克罗恩病小肠蠕动的定量,验证和随访

获取原文

摘要

The use of magnetic resonance enterography (MRE) has become a mainstay in the evaluation, assessment and follow up of inflammatory bowel diseases, such as Crohn's disease (CD), thanks to its high image quality and its non-ionizing nature. In particular, the advent of faster MRE sequences less sensitive to image-motion artifacts offers the possibility to obtain visual, structural and functional information of the patient's small bowel. However, the inherent subjectivity of the mere visual inspection of these images often hinders the accurate identification and monitoring of the pathological areas. In this paper, we present a framework that provides quantitative and objective motility information of the small bowel from free-breathing MRE dynamic sequences. After compensating for the breathing motion of the patient, we create personalized peristaltic activity maps via optical flow analysis. The result is the creation of a new set of images providing objective and precise functional information of the small bowel. The accuracy of the new method was also evaluated from two different perspectives: objective accuracy (1.1 ± 0.6 mm/s of error), i.e., the ability of the system to provide quantitative and accurate information about the motility of moving bowel landmarks, and subjective accuracy (avg. difference of 0.7 ± 0.7 in a range of 1 to 5), i.e., the degree of agreement with the subjective evaluation of an expert. Finally, the practical utility of the new method was successfully evaluated in a preliminary study with 32 studies of healthy and CD cases, showing its potential for the fast and accurate assessment and follow up of CD in the small bowel.
机译:由于其高图像质量和非电离性质,磁共振肠造影(MRE)的使用已成为评估,评估和随访炎症性肠病(如克罗恩病(CD))的主要手段。特别地,对图像运动伪影不那么敏感的更快的MRE序列的出现提供了获得患者小肠的视觉,结构和功能信息的可能性。然而,仅对这些图像进行视觉检查的固有主观性常常妨碍对病理区域的准确识别和监测。在本文中,我们提出了一个框架,该框架从自由呼吸的MRE动态序列中提供了小肠的定量和客观运动信息。在补偿患者的呼吸运动后,我们通过光流分析创建个性化的蠕动活动图。结果是创建了一组新图像,这些图像提供了小肠的客观,精确的功能信息。还从两个不同的角度评估了新方法的准确性:客观准确性(1.1±0.6 mm / s的误差),即系统能够提供有关运动中的肠标志物运动性的定量和准确信息的能力以及主观性准确度(在1到5的范围内,平均差异为0.7±0.7),即与专家的主观评价相一致的程度。最后,在一项针对32例健康和CD病例的初步研究中成功评估了该新方法的实用性,显示了其对小肠CD的快速准确评估和随访的潜力。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号