首页> 外文会议>European corrosion congress >Comparison of atmospheric corrosion of ACM sensors with standard flat specimens
【24h】

Comparison of atmospheric corrosion of ACM sensors with standard flat specimens

机译:ACM传感器与标准扁平样品的大气腐蚀比较

获取原文
获取外文期刊封面目录资料

摘要

The Fe-Ag type Atmospheric Corrosion Monitor (ACM) sensors can be used for monitoring the corrosion rate and corrosivity of various atmospheric conditions in a shorter time than the exposure test according to EN ISO 9223. The correlation between the corrosion rate of carbon steel standard flat specimens and the ACM sensors' output sensors was tested in the Czech Republic in 2013 - 2014 under outdoor and sheltered conditions at two locations: Prague, and Kopisty, representing urban, respectively industrial environments. Corrosion rates of one month exposure test were plotted as a function of the ACM sensors output to evaluate their relationships. The environmental parameters were measured continually on both atmospheric test sites too.
机译:Fe-Ag型大气腐蚀监测器(ACM)传感器可用于监测各种大气条件的腐蚀速率和腐蚀性,比en ISO 9223的曝光试验更短的时间。碳钢标准腐蚀速率之间的相关性扁平标本和ACM传感器的输出传感器在2013年 - 2014年在户外和庇护的条件下在两个地点(Prague)和Kopisty分别代表城市,分别为工业环境。作为ACM传感器输出的函数绘制了一个月曝光测试的腐蚀速率,以评估其关系。环境参数也在两种大气测试部位上持续测量。