首页> 外文会议>ASME international technical conference and exhibition on packaging and integration of electronic and photonic microsystems >IMPROVING THE THERMAL PERFORMANCE OF A FORCED CONVECTION AIR COOLED SOLUTION - PART 1: MODIFICATION OF HEAT SINK ASSEMBLY
【24h】

IMPROVING THE THERMAL PERFORMANCE OF A FORCED CONVECTION AIR COOLED SOLUTION - PART 1: MODIFICATION OF HEAT SINK ASSEMBLY

机译:改善强制对流空气冷却溶液的热性能-第1部分:热沉组件的改性

获取原文

摘要

Forced convection air cooling using heat sinks is one of the most prevalent methods in thermal management of microelectronic devices. Improving the performance of such a solution may involve minimizing the external thermal resistance (R_(ext)) of the package. For a given heat sink design, this can be achieved by reducing the thermal interface material (TIM) thickness through promotion of a uniform interfacial pressure distribution between the device and heat sink. In this study, a dual-CPU rackmount server is considered and modifications to the heat sink assembly such as backplate thickness and bolting configuration are investigated to achieve the aforementioned improvements. A full-scale, simplified model of the motherboard is deployed in ANSYS Mechanical, with emphasis on non-linear contact analysis and torque analysis of spring screws, to determine the optimal design of the heat sink assembly. It is observed that improved interfacial contact and pressure distribution is achieved by increasing the number of screws (loading points) and positioning them as close to the contact area as possible. The numerical model is validated by comparison with experimental measurements within reasonable accuracy. Based on the results of numerical analysis, the heat sink assembly is modified and improvement over the base configuration is experimentally quantified through interfacial pressure measurement. The effect of improved interfacial contact on thermal performance of the solution is discussed.
机译:使用散热器的强制对流空气冷却是微电子设备热管理中最流行的方法之一。改善这种解决方案的性能可能涉及最小化封装的外部热阻(R_(ext))。对于给定的散热器设计,这可以通过促进设备和散热器之间的均匀界面压力分布来减小热界面材料(TIM)的厚度来实现。在这项研究中,考虑了双CPU机架式服务器,并研究了对散热器组件的修改,例如背板厚度和螺栓配置,以实现上述改进。在ANSYS Mechanical中部署了主板的完整简化模型,重点是弹簧螺丝的非线性接触分析和扭矩分析,以确定散热器组件的最佳设计。可以观察到,通过增加螺钉(加载点)的数量并将其放置在尽可能靠近接触区域的位置,可以改善界面接触和压力分布。通过在合理的精度范围内与实验测量值进行比较来验证数值模型。根据数值分析的结果,对散热器总成进行了修改,并通过界面压力测量以实验方式量化了对基本配置的改进。讨论了改进的界面接触对溶液热性能的影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号