首页> 外文会议>IEEE Nuclear Science Symposium and Medical Imaging Conference >A comparison of breast lesion imaging capability of a whole-body PET camera and a brain/breast PET camera
【24h】

A comparison of breast lesion imaging capability of a whole-body PET camera and a brain/breast PET camera

机译:全身宠物摄像头乳房病变成像能力和大脑/乳房宠物摄像头的比较

获取原文

摘要

PET scanners have been used for the diagnosis, staging, and management of a variety of malignancies, including breast cancer. However, despite the powerful molecular imaging nature of PET, the resolution and sensitivity of current PET cameras practically limit the detection of breast lesions to relatively large lesion (≫7 mm) and high tracer uptakes. Improvements in spatial resolution and sensitivity of PET cameras are essential for early detection of small breast lesions (≪5 mm) which is critical to the early detection and successful treatment of breast cancer. Recently, we have completed the construction of a high-resolution and high-sensitivity PET camera (HOTPET). HOTPET has spatial resolution of better than 3 mm and can operate in the whole-body mode or breast/brain mode. In the whole-body mode HOTPET has transverse field-of-view (FOV) of 60 cm and axial FOV of 13 cm. In the breast/brain mode it has transverse FOV of 39 cm and axial FOV of 21 cm. We have performed a detailed phantom study of the breast lesion detection capability of HOTPET in both modes using a breast phantom with lesion insert. The breast phantom was attached to a torso phantom with lung, liver, spine and cardiac inserts. We scanned 2 small lesions with diameter of 4.95 and 7.86 mm for several lesion activity contrasts. The standard uptake value (SUV) of lesion was in range of 1 to 10. The SUV of the breast, torso and heart were 0.8, 1, and 4, respectively. Visual inspection of the images showed that the small 4.95-mm lesion with SUV of 2.5 or higher was observable in HOTPET breast mode data and with SUV of 5.5 or higher in the whole-body mode data. The 7.86 mm lesion was observable with SUV of 1.75 in breast mode and SUV of 2.5 in whole-body mode.
机译:宠物扫描仪已被用于各种恶性肿瘤的诊断,分期和管理,包括乳腺癌。然而,尽管宠物的强大分子成像性质,但电流宠物摄像机的分辨率和敏感性几乎限制了乳腺病变的检测到相对大的病变(»7 mm)和高示踪剂上升。宠物摄像机的空间分辨率和敏感性的改善对于早期检测小乳腺​​病变(«5 mm)至关重要,这对于早期检测和成功治疗乳腺癌至关重要。最近,我们已经完成了高分辨率和高灵敏度宠物摄像头(热偶)的构建。热偶的空间分辨率优于3毫米,可以在全身模式或乳房/脑模式下操作。在全体模式热销中,热横场(FOV)为60cm,轴向FOV为13厘米。在乳房/脑模式中,它具有39cm的横向FOV,轴向FOV为21厘米。我们在使用具有病变插入物的乳房幻影的两种模式中对热位的乳房病变检测能力进行了详细的幻像研究。乳房幻影与肺,肝,脊柱和心脏插入躯干幻影附着。对于几种病变活动对比,我们扫描2个直径为4.95和7.86毫米的小病变。病变的标准摄取值(SUV)是乳房的1〜10,SUV范围,躯干和心脏分别为0.8,1和4。图像的目视检查显示,在热销乳房模式数据中可观察到具有2.5或更高的4.95毫米的病变,并且在全身模式数据中具有5.5或更高的SUV。 7.86 mm病变可观察到1.75的乳房模式和全身模式的SUV为2.5。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号