首页> 外文会议>International exhibition conference for power electronics, intelligent motion, renewable energy and energy management >Localization of electrical active defects on power devices using Lock - in Thermography and thermal trigger delay
【24h】

Localization of electrical active defects on power devices using Lock - in Thermography and thermal trigger delay

机译:使用锁定热成像和热触发延迟定位功率设备上的电活动缺陷。

获取原文
获取外文期刊封面目录资料

摘要

In this paper, the method of Lock-in Thermography is presented which is an enhanced Thermography method leading to high spatial resolution (~1μm) and high sensitivity (single μW). Thus, the method enables thermal investigations for fault isolation (e.g. electrical shorts) on power devices. Based on case studies, the operational principle and the advantages for non-destructive defect localization are shown. These case studies include the possibility of detecting electrical active defects buried under metal layer and in close distance to bond wires as well as the prediction of break-down positions. As a second key aspect, the method of thermal trigger delay is introduced and applied for high temporal thermal imaging of fast thermal events such as investigations focused on device switching characteristics.
机译:本文介绍了锁定热成像方法,它是一种增强的热成像方法,具有较高的空间分辨率(〜1μm)和高灵敏度(单μW)。因此,该方法使得能够进行热检查以进行功率设备上的故障隔离(例如,电短路)。在案例研究的基础上,展示了无损缺陷定位的工作原理和优势。这些案例研究包括检测掩埋在金属层下并与键合线相距很近的电活性缺陷的可能性,以及预测击穿位置的可能性。作为第二个关键方面,引入了热触发延迟方法,并将其应用于快速热事件的高时间热成像,例如针对设备开关特性的研究。