Using a Hybrid III Anthropomorphic Test Device with Back Constraint to Evaluate Robot Impact to the Chest

机译:使用带有后约束的混合III拟人测试装置,以评估胸部的机器人撞击

获取原文

摘要

Impact tests using an Anthropomorphic Test Device (ATD) or a dummy were conducted to assess the risk that a moving mass, such as a robot, might pose to an individual against a stationary constraint. A mathematic model was also used to simulate the dummy's responses to impacts from different combinations of mass and velocity. The results showed that the sternum-to-spine deflection, or chest compression, was higher when the dummy's back was constrained than when it was unconstrained. A study plan for understanding the risk from a moving mass such as a robot was proposed.
机译:进行了使用拟人测试装置(ATD)或虚设的冲击试验以评估移动质量(例如机器人)可能对个体施加到静止约束的风险。数学模型也用于模拟虚拟的响应,从质量和速度的不同组合的影响。结果表明,当假人的背部受到约束时,胸骨到脊柱偏转或胸部压缩较高,而不是无约束。提出了一种理解诸如机器人等运动质量的风险的研究计划。