首页> 外文会议>World Congress on Medical Physics and Biomedical Engineering >Basic Study of the Imaging Conditions on Tumor Volume Measurement Using 3D-MR Imaging of the Liver While Patient Holds Breath
【24h】

Basic Study of the Imaging Conditions on Tumor Volume Measurement Using 3D-MR Imaging of the Liver While Patient Holds Breath

机译:使用肝脏三维MR成像的肿瘤体积测量成像条件的基本研究

获取原文

摘要

Tumor volumetric measurement using liver 3D-MR imaging tends to cause measurement errors because the liver moves with the diaphragm during imaging while the patient is holding the breath.The breath holding method of the patient when 3D-MR imaging for measurement of tumor volume was performed was discussed using a movable simulated tumor phantom.Furthermore,optimal imaging conditions(breath holding method,slice section,voxel setting and phase encoding direction)with the least influence by body motion were studied.Based on three breath holding methods,the simulated phantom was moved in the direction of the foot-head along the line of the MRI receiver coil.The image sequence was a 3D-T1 weighted fast field echo method.The imaging time was fixed at 20 s.As a result,the breath holding method with the smallest measured volume error is functional residual capacity(FRC)breath hold(0.1 mm/s).The optimum imaging condition is when the imaging section is set in the axial direction and the phase encoding direction is perpendicular to the moving direction with an iso voxel as small as possible.In the case where it is necessary to set the phase encoding in the direction parallel to the proceeding direction,imaging with the setting of rectangular voxel can suppress the measurement error of the volume.In order to measure accurate volume using liver 3D-MR imaging,it is necessary to know the direction of movement of the tumor during respiration and to set appropriate breath holding method,section,phase encoding direction and voxel size.
机译:使用肝脏3D-MR成像的肿瘤体积测量趋于引起测量误差,因为肝脏在成像期间与隔膜一起移动,而患者保持呼吸。患者的呼吸保持方法在进行肿瘤体积的测量3D-MR成像时进行患者使用动身模拟肿瘤幻像进行了讨论的。在三次呼吸持有方法上,使用了具有最小影响的可移动模拟肿瘤幻影。在三次呼吸持有方法上,逐步讨论了具有最小的体内运动的最小影响。基于三次呼吸沿着MRI接收器线圈的线沿脚头的方向移动。图像序列是3D-T1加权快速场回波方法。成像时间在20 s中固定。结果,呼吸保持方法最小的测量体积误差是功能性残留容量(FRC)呼吸保持(0.1 mm / s)。最佳成像条件是在轴向和eN中设置成像部分时编码方向垂直于移动方向与ISO体素尽可能小。在需要在与程序的方向上的方向设置相位编码的情况下,与矩形voxel的设置成像可以抑制测量误差体积的顺序使用肝脏3D-MR成像来测量精确的体积,有必要知道呼吸过程中肿瘤的运动方向,并设定适当的呼吸保持方法,截面,相编码方向和体素尺寸。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号