首页> 外文会议>World Congress on Medical Physics and Biomedical Engineering >Dosimetric Verification for Tangential Breast Irradiation in Commercial Treatment Planning System Using Indigenous Female Wax Torso
【24h】

Dosimetric Verification for Tangential Breast Irradiation in Commercial Treatment Planning System Using Indigenous Female Wax Torso

机译:用土着女性蜡躯干商业治疗规划系统切向乳房辐射的剂量验证

获取原文

摘要

Accuracy of Clarkson algorithm employed in a commercial 3D TPS was evaluated for conditions simulating tangential breast treatment. A breast phantom was fabricated from machineable wax to examine the accuracy of tangential breast irradiation. This Paper specifically describes the use of unique self-designed wax breast phantom to validate the accuracy of three-dimensional dose calculations performed by Xio-CMS planning system for breast tangential irradiation. Steven et all(l)has done a related study using anthropomorphic breast phantom .In our study the accuracy of dose calculations has been verified using 0.6cc ionization chamber. The treatment plans has been generated using the combined 6 and 15 MV photon beams and field in field technique. Measured doses have been compared to those calculated from the treatment planning system and found to be in good agreement with previously published results. Our results indicates that the inexpensive wax phantom can be used for verification in absence of expensive anthropomorphic breast phantom which may be of great help for verification of 3D breast plans in developing countries.
机译:在模拟切向乳房处理的条件下评估商业3D TPS中采用的Clarkson算法的准确性。乳房幻影由可处理的蜡制成,以检查切向乳房辐射的准确性。本文具体描述了使用独特的自动设计蜡乳房幻影,以验证XIO-CMS计划系统进行乳房切向照射的三维剂量计算的准确性。 Steven et全(L)使用拟人乳房幻影进行了相关的研究。我们的研究已经使用0.6cc电离室验证了剂量计算的准确性。已经使用基础技术中的组合的6和15 MV光子束和场产生了处理计划。已经将测量剂量与来自治疗计划系统计算的那些进行了比较,发现与先前已发表的结果吻合良好。我们的结果表明,廉价的蜡幻影可用于验证昂贵的拟人乳房幻影,这可能有很大帮助验证发展中国家的3D乳房计划。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号