Wavelength Modulation Spectroscopy Tomography (WMST) has been widely used for imaging of critical flame parameters, e.g. temperature distribution and species concentration distribution, in harsh environments. To better characterize turbulent flows in practical applications, it is highly desired to improve the temporal resolution of the WMST method. This paper presents a quasi-parallel data acquisition scheme for WMST, which can maintain the temporal response of a fully parallel system with cost-effective hardware implementation. The key idea is to multiplex among the channels on the fast modulated periods within each wavelength scan. The proposed method was validated by four-channeL quasi-parallel data acquisition of the absorption data using a customized FPGA platform. The results show that accurate harmonics information can be extracted simultaneously for each multiplexed channel.
机译:波长调制光谱层析成像(WMST)已广泛用于临界火焰参数的成像,例如,温度分布和物种浓度分布,在恶劣环境中。为了更好地表征在实际应用中的湍流流动,因此非常需要提高WMST方法的时间分辨率。本文提出了一种用于WMST的准平行数据采集方案,其可以通过具有成本效益的硬件实现来维持完全并行系统的时间响应。关键思想是在每个波长扫描内的快速调制周期内的信道中复用。通过使用定制的FPGA平台,通过四通道准平行数据获取的四通道准平行数据采集验证了所提出的方法。结果表明,可以针对每个多路复用信道同时提取准确的谐波信息。