Modern-day DC powered light rail lines are designed with many effective stray current control features built-in, principally an electrically ungrounded traction power negative return circuit. This often includes track construction measures intended to establish much higher track-to-earth resistances when compared to the streetcars of long ago. This attribute dramatically reduces stray current leakage to tolerable levels with limited if any negative impact on underground pipeline corrosion control. Case histories of water pipelines constructed near light rail lines built within the last nine years are reviewed. Results of field evaluations in Sacramento, Salt Lake City and Minneapolis are presented. Guidelines for stray current corrosion protection strategies for ductile iron pipelines are provided.
机译:现代DC动力轻轨线采用内置多种有效杂散电流控制功能,主要是电解未接地的牵引力负返回电路。这通常包括轨道施工措施,旨在在与很久以前的路牌相比时建立更高的轨道接地电阻。此属性显着降低了杂散电流泄漏,以受阻的水平,有限,如果对地下管线腐蚀控制有任何负面影响。综述了在最近九年内建造的近九年内建造的水管道的案例历史。提出了萨克拉门托,盐湖城和明尼阿波利斯的现场评估结果。提供了用于脱髓鞘管道的杂散电流腐蚀保护策略指南。