We proposed a new method to calculate the total amounts of the indoor pollutants based on integration concept and compared with the standards of total emissions in IAQ. In this study, suggested methods applied on the hourly data, which is measured from January to December 2009. For establishing the standards for total emissions, we suggested a new calculation method, multiplying with 24 to the current standard concentration of each pollutant of IAQ. So the total emissions of IAQ are calculated and compared the standards of total emissions. It is clear from the results that the concentration of NO_2 exceeded the standards of total emission in spring and fall seasons.
机译:我们提出了一种基于集成概念的室内污染物总量计算方法,并与室内空气质量总量标准进行了比较。在这项研究中,建议的方法应用于从2009年1月至2009年12月测量的小时数据。为建立总排放标准,我们提出了一种新的计算方法,将IAQ每种污染物的当前标准浓度乘以24。因此,要计算IAQ的总排放量,并比较总排放量的标准。从结果可以明显看出,春季和秋季,NO_2的浓度超过了总排放标准。