摘要

The authors present a paper on the application of online partial discharge (PD) testing and monitoring technology for the insulation condition assessment of in service medium voltage (MV — 3.3kV to 45kV)) and high voltage (HV — 66kV to 750kV) cables and plant. The paper begins with a short summary of the different economic ‘DRIVERS’ which apply to both public utility and industrial HV networks. The paper presents some of the test techniques employed and the on-line PD sensor technology used to test in-service power cables, switchgear, transformers, rotating machines, CTs/VTs and other HV plant. The paper concludes with some case studies of past projects carried out by the authors from on-line PD test projects testing a wide range of MV & HV assets in electricity networks around the world.
机译:作者介绍了在线局部放电(PD)测试和监测技术在服务中电压(MV — 3.3kV至45kV)和高压(HV — 66kV至750kV)电缆的绝缘状况评估中的应用,以及植物。本文首先简要介绍了适用于公用事业和工业高压网络的不同经济“驱动因素”。本文介绍了一些测试技术以及用于测试在役电力电缆,开关柜,变压器,旋转机,CT / VT和其他高压设备的在线PD传感器技术。本文以作者对过去的项目进行的一些案例研究作为结束,这些案例是作者从在线PD测试项目中进行的,这些项目测试了世界范围内电网中的各种MV和HV资产。