Estimation of bone mineral density from the digital image of the calcanium bone

机译:从跟骨骨的数字图像估计骨矿物质密度

获取原文

摘要

Osteoporosis is more commonly seen in routine clinical practices, and its affects post-menopausal women, and elderly of both sexes. In India, it is more prevalent due to the mal-nutritional status, vitamin D deficiency, and lack of physical activity of majority of the general population. Bone strength is determined by its quality and its density. Bone mineral density (BMD) can be measured non-invasively by several techniques. Radiographic absorptiometry (RA) is one of the oldest methods of measurement of BMD from the conventional radiograph exposed simultaneously with a calibration phantom. Dual energy x-ray absorptiometry (DXA) is the ‘gold’ standard for measuring BMD (g cm−2). The aim of this pilot study was to estimate BMD (Est-BMD) of the calcaneous from the radiograph with good accuracy using RA technique. A total number of 19 Indian women, aged above 20 years were included in the study. Each woman, BMD of the right proximal femur was measured by DXA; also, a standard digital x-ray of right proximal femur exposed along with a small size step-wedge bone phantom was obtained. From the image, the mean grey level (MGL) values were measured in each defined region of interest (ROI) as well as in each step of the phantom. The measured MGL values of all the steps as well as their corresponding known BMD (g cm−3) values were used to plot the calibration curve. It was found that there was a statistically significant (p=0.001) correlation (r2=0.93) between the mean MGL values and their corresponding known bone phantom BMD values. In the obtained linear regression equation, the measured mean MGL on various ROI''s of the calcaneous were substituted separately and their corresponding BMD (g cm−2) values were estimated. WHO''s diagnostic criteria was used for the disease. In all women (n=19), Est-BMD at centre ROI of the calcaneous was correlated significantly (p&x003-;-D;0.05) with femur neck BMD, N-BMD (r2=0.19), total hip BMD, T-BMD (r2=0.24), and shaft BMD, S-BMD (r2=0.24) of the proximal femur measured by DXA. In osteoporotic women group, the percentage decreases in DXA-BMD of different region of interest (ROI)''s of the proximal femur were ranged from 26.9% to 46.7%, when compared to normal healthy women, and it was high in T-BMD. On the other hand, in osteoporotic women, the percentage decrease in Est-BMD of the calcaneous in different ROI''s were ranged from 7.5% to 13.6% when compared to normal women, and it was high in the centre ROI of the bone. It requires a calibration study using either European spine phantom or Hologic''s spine phantom to test the accuracy of the method. Also, it requires further trials with more number of patients with and without osteoporotic fractures to test its predictability of future fracture risk.
机译:在常规临床实践中更常见的骨质疏松症,其影响绝经后妇女和两性的老年人。在印度,由于营养状况,维生素D缺乏症,缺乏大多数一般人群的身体活动更为普遍。骨强度取决于其质量及其密度。骨矿物密度(BMD)可以通过几种技术进行非侵入性。射线照相吸收测量法(RA)是从传统射线照片与校准模拟的传统射线照片测量BMD的最旧方法之一。双能X射线吸收测定法(DXA)是用于测量BMD的“金”标准(G CM -2 )。该试点研究的目的是使用RA技术具有良好的精度,从射线照片估算切片的BMD(EST-BMD)。在研究中,达到了20岁以上的19名印度妇女总数。每个女人,右侧股骨的BMD由DXA测量;此外,获得了与小尺寸阶梯骨模侧暴露的右侧股骨的标准数字X射线。从图像中,在每个定义的感兴趣区域(ROI)以及幻像的每个步骤中测量平均灰度级(MGL)值。所有步骤的测量MGL值以及它们相应的已知BMD(GCM -3 / sup>)值用于绘制校准曲线。发现平均MGL值与其相应的已知骨骼模型BMD值之间存在统计学上显着的(P = 0.001)相关(R 2 = 0.93)。在所获得的线性回归方程中,估计同果翻译的各种ROI'的测量平均MGL被分别取代,并且估计它们的相应的BMD(GCM -2)值。世卫组织的诊断标准用于该疾病。在所有女性(n = 19)中,果皮中心ROI的EST-BMD显着相关(P&x003-; - D; 0.05)与股骨颈部BMD,N-BMD(R 2 = 0.19),总髋部BMD,T-BMD(R 2 = 0.24),以及轴BMD ,由DXA测量的近端股骨的S-BMD(R 2 = 0.24)。在骨质疏松妇女组中,与正常健康女性相比,近端股骨不同地区(ROI)的DXA-BMD的百分比下降(ROI)'的近端股骨的百分比范围为26.9%至46.7%,并且它在T-中很高BMD。另一方面,在骨质疏松妇女中,与常规女性相比,在不同ROI的果皮中EST-BMD的百分比降低至7.5%至13.6%,并且在骨骼的中心ROI中很高。它需要使用欧洲脊柱幻影或HOLOGIC'的脊柱幻影来测试方法的校准研究来测试该方法的准确性。此外,它需要进一步试验更多有更多数量的患者,无骨质疏松骨折,以测试其未来裂缝风险的可预测性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号