首页> 外文会议>Conference on image perception, observer performance, and technology assessment >Measurement of breast lesion display luminance and overall image display luminance relative to optimum luminance for contrast perception
【24h】

Measurement of breast lesion display luminance and overall image display luminance relative to optimum luminance for contrast perception

机译:相对于最佳对比度的相对于最佳亮度的乳房病变显示亮度和整体图像显示亮度的测量

获取原文

摘要

Introduction: To minimize fatigue due to eye adaptation and maximize contrast perception, it has been suggested that lesion luminance be matched to overall image luminance to perceive the greatest number of grey level differences. This work examines whether lesion display luminance matches the overall image and breast tissue display luminance and whether these factors are positioned within the optimum luminance for maximal contrast sensitivity. Methods: A set of 42 mammograms, collected from 21 patients and containing 15 malignant and 6 benign lesions, was used to assess overall image luminance. Each image displayed on the monitor was divided into 16 equal regions. The luminance at the midpoint of each region was measured using a calibrated photometer and the overall image luminance was calculated. Average breast tissue display luminance was calculated from the subset of regions containing of only breast tissue. Lesion display luminance was compared with both overall image display luminance and average breast tissue display luminance. Results: Statistically significant differences (p<0.0001) were noted between overall image display luminance (4.3±0.7 cd/m2) and lesion display luminance (15.0±6.8 cd/m2); and between average breast tissue display luminance (6.8±1.3 cd/m2) and lesion display luminance (p<0.002). Conclusions: Lesion luminance was significantly higher than the overall image and breast tissue luminance. Luminance of lesions and general breast tissue fell below the optimum luminance range for contrast perception. Breast lesion detection sensitivity and specificity may be enhanced by use of brighter monitor displays.
机译:简介:为了最大程度地减少由于眼睛适应引起的疲劳并最大化对比度感知,建议将病变亮度与整体图像亮度匹配,以感知最大数量的灰度级差异。这项工作检查病变显示亮度是否与整个图像和乳房组织显示亮度相匹配,以及这些因素是否位于最佳亮度下以实现最大的对比度敏感度。方法:从21例患者中收集的42例乳房X线照片用于评估整体图像亮度,其中包括15例恶性病变和6例良性病变。显示屏上显示的每个图像均分为16个相等的区域。使用校准的光度计测量每个区域的中点的亮度,并计算整体图像亮度。从仅包含乳房组织的区域的子集计算出平均乳房组织显示亮度。将病变显示亮度与整体图像显示亮度和平均乳房组织显示亮度两者进行比较。结果:总体图像显示亮度(4.3±0.7 cd / m2)和病变显示亮度(15.0±6.8 cd / m2)之间存在统计学上的显着差异(p <0.0001);在平均乳腺组织显示亮度(6.8±1.3 cd / m2)和病变显示亮度(p <0.002)之间。结论:病变亮度明显高于整体图像和乳腺组织亮度。病变和一般乳房组织的亮度低于对比度感知的最佳亮度范围。乳腺病变检测的敏感性和特异性可以通过使用更明亮的监视器显示来增强。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号