The purpose of this study was to compare the performances of two recently-developed image retrieval methods for mammographic masses, and to investigate the inter- and intra-observer variability in radiologists' assessment of mass similarity. Method 1 retrieved masses that are similar to a query mass from a reference library based on radiologists' margin and shape descriptions and the mass size. Method 2 used computer-extracted features. Two MQSA radiologists participated in an observer study in which they rated the similarity between 100 query masses and the retrieved lesions based on margins, shape, and size. For each query mass, three masses retrieved using Method 1 and three masses retrieved using Method 2 were displayed in random order using a graphical user interface. A nine-point similarity rating scale was used, with a rating of 1 indicating lowest similarity. Each radiologist repeated the readings twice, separated by more than three months, so that intra-observer variability could be studied. Averaged over the two radiologists, two readings, and all masses, the mean similarity ratings were 5.59 and 5.57 for Methods 1 and 2, respectively. The difference between the two methods did not reach significance (p>0.20) for either radiologist. The intra-observer variability was significantly lower than the inter-observer variability, which may indicate that each radiologist may have their image similarity criteria, and the criteria may vary from radiologist to radiologist. The understanding of the trends in radiologists' assessment of mass similarity may guide the development of decision support systems that make use of mass similarity to aid radiologists in mammographic interpretation.
机译:本研究的目的是比较乳房X线肿块的两个最近开发的图像检索方法的性能,并研究放射科学家对质量相似性评估的间歇性变异性。方法1检索与来自参考文库的查询质量相似的肿块,基于放射学者的余量和形状描述和质量尺寸。方法2使用计算机提取的特征。两个MQSA放射科医生参加了一个观察者研究,它们在其中额定了100个查询质量和基于边缘,形状和尺寸的检索的病变之间的相似性。对于每个查询质量,使用使用图形用户界面以随机顺序显示使用方法1和检索的三个质量检索的三个肿块。使用九点相似度评级,具有1表示最低相似性的额定值。每个放射科医生重复读数两次,分开超过三个月,从而可以研究观察者内的变异性。平均在两个放射科医生,两个读数和所有质量,平均相似度评级分别为5.59和5.57,分别用于1和2。两种方法之间的差异未达到无论放射科医师的意义(p> 0.20)。观察室内的变异性显着低于观察者间变异性,这可能表明每个放射科学家可能具有它们的图像相似标准,并且标准可能因放射科学家而异。对放射科学家评估的趋势的理解可以指导决策支持系统的发展,这些支持系统利用质量相似性与乳房XMAMPOCH解释的援助放射科医师。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号