首页> 外文会议>Conference on cryogenic optical systems and instruments >Compensation for 6.5-K cryogenic distortion of a fused quartz mirror by refiguring
【24h】

Compensation for 6.5-K cryogenic distortion of a fused quartz mirror by refiguring

机译:通过补充补偿融合石英镜的6.5-k低温扭曲

获取原文

摘要

A 46 cm diameter, lightweight, Amersil TO8E, fused-natural-quartz mirror with a single-arch cross section was tested at the NASA-Ames Research Center Cryogenic Optical Test Facility to measure its cryogenic distortion at 6.5 K. Then the mirror was refigured with the inverse of the measured cryogenic distortion to compensate for this figure defect. The mirror was retested at 6.5 K and found to have a significantly improved figure. The compensation for cryogenic distortion was not complete, but preliminary analysis indicates that the compensation was better than 0.25 waves P-V if edge effects are ignored. The feasibility of compensating for cryogenic distortion by refiguring has thus been verified.
机译:在NASA-AMES研究中心低温测试设施中测试了46厘米的直径,轻盈的Amersil To8e,融合 - 天然石英镜,带有单拱形横截面的融合 - 横截面,在6.5 k下测量其低温失真。然后镜子被灌注通过测量的低温变形的倒数来补偿该数字缺陷。镜子在6.5 k处重新测试,发现具有显着改善的数字。低温失真的补偿不完整,但初步分析表明,如果忽略边缘效应,则补偿优于0.25波P-V。因此,已经验证了通过补充补偿冷冻畸变的可行性。