首页> 外文会议>Self-Calibrated Intelligent Optical Sensors and Systems >Novel white-light interferometer using an electronically scanned Mach-Zehnder interferometer
【24h】

Novel white-light interferometer using an electronically scanned Mach-Zehnder interferometer

机译:使用电子扫描的马赫曾德尔干涉仪的新型白光干涉仪

获取原文

摘要

Abstract: A theoretical analysis and experimental evaluation of a novel Mach-Zehnder interferometer (MZI), used as a recovery interferometer in an electronically-scanned white-light interferometer is reported. This modified version of a MZI has the advantages of being very simple and compact, with high stability and does not introduce any spatial `misoverlapping' of the beams. In addition, since only one beamsplitter is employed in the interferometer (instead of the usual two used in a conventional MZI), the system is relatively easy to implement and at low cost. Furthermore, this configuration can be simply set to cover a wide range of optical path difference values by simply changing the angle and position of one of the mirrors. This gives the interferometer the advantage of being easily adapted for a range of different measurement applications.!7
机译:摘要:报道了一种新型的马赫曾德尔干涉仪(MZI)的理论分析和实验评估,该干涉仪用作电子扫描白光干涉仪中的恢复干涉仪。 MZI的这种修改版本具有非常简单和紧凑,具有高稳定性的优点,并且不会引入光束的任何空间“重叠”。另外,由于在干涉仪中仅采用了一个分束器(而不是在常规MZI中使用的通常的两个分束器),因此该系统相对易于实现且成本较低。此外,通过简单地改变其中一个镜的角度和位置,可以简单地将该配置设置为覆盖宽范围的光程差值。这使干涉仪具有易于适应各种不同测量应用的优势。!7