首页> 外文会议>IEEE Electronic Components and Technology Conference >Investigation and Comparison of Aging Effects in SAC+X Solders Exposed to High Temperatures
【24h】

Investigation and Comparison of Aging Effects in SAC+X Solders Exposed to High Temperatures

机译:SAC + X焊料在高温下老化效应的调查与比较

获取原文

摘要

Microstructural evolution occurs in lead free Sn-Ag- Cu (SAC) solder joints exposed to isothermal aging. Such changes lead to degradations in the mechanical properties and creep behavior of the solder, and can result in dramatic reductions in the board level reliability of lead-free electronic assemblies subjected to aging. In our recent research, Scanning Electron Microscopy (SEM) has been used to: (1) monitor aging induced microstructural changes occurring within fixed regions in selected lead-free solder joints, (2) create time-lapse imagery of the microstructure evolution, and (3) analyze the microstructural changes quantitatively and correlate to the observed mechanical behavior evolution. This approach has removed the limitations of many prior studies where aged and non-aged microstructures were taken from two different samples and could only be qualitatively compared.In our recent papers presented at ECTC 2018 and 2019, the developed approach was used to observe the microstructure evolutions in SAC305 (96.5Sn-3.0Ag-0.5Cu) and SAC_Q (SAC+Bi) solder joint samples for up to 2000 hours of aging at T = 125 °C. In the current study, we have extended this work for longer aging times up to 7000 hours, and we have also examined microstructural changes for aging at another temperature (T = 100 °C). Finally, a more extensive study has been performed for short term aging up to 270 hours, which is when the majority of aging induced changes occur. The aging induced changes in microstructure have been correlated with the changes in mechanical behavior measured using uniaxial tensile testing.The area and diameter of each IMC particle were tracked during the aging process using the recorded images and imaging processing software. As expected, the analysis of the evolving SAC305 and SAC_Q microstructures showed a significant amount of diffusion of silver and bismuth in the beta-tin matrix during aging. In particular, Ag3Sn particles coalesced during aging leading to a decrease in the number of particles. Any bismuth in the SAC_Q microstructure was observed to quickly go into solution, resulting in solid solution strengthening. This primary occurred within the beta-Sn dendrites, but also in the Ag3Sn intermetallic rich regions between dendrites. The presence of bismuth in was also found to slow the diffusion process that coarsens the Ag3Sn IMC particles. The combination solid solution strengthening and a lower diffusion rate for Ag lead to reduced aging effects in the SAC+Bi alloy relative to the SAC305 solder alloy.The mechanical behavior degradations in the two alloys were also investigated. Before testing, the solder uniaxial specimens were aged (preconditioned) at T = 125 °C. At each aging temperature, several durations of aging were considered including 0, 2, 6, 12, and 24 hours. Uniaxial tensile tests were then performed on the aged specimens at high temperature (T = 125 °C). Using the measured data, the evolutions of the high temperature stress-strain behavior were determined as a function of aging temperature and aging time, and models describing the evolution of the mechanical properties with extreme aging were established.The SAC_Q alloy was found to have significantly better high temperature mechanical properties relative to SAC305 at all prior aging conditions. In particular, the initial modulus and ultimate tensile strength of SAC305 experienced large degradations during high temperature aging, whereas the same properties of SAC_Q changed only slightly. These changes in mechanical behavior correlated well with the observed increases in the average IMC particle diameter and decreases in the number of IMC particles. The microstructural and material property degradations were especially large for SAC305 during the initial 50 hours of aging.
机译:微结构演变发生在暴露于等温老化的无铅锡-银-铜(SAC)焊点中。这种变化会导致焊料的机械性能和蠕变行为下降,并可能导致无铅电子组件的板级可靠性大幅下降。在我们最近的研究中,扫描电子显微镜(SEM)已用于:(1)监视老化引起的选定无铅焊点中固定区域内发生的微观结构变化,(2)创建微观结构演变的延时图像,以及(3)定量分析微观结构变化,并与观察到的力学行为演变相关。这种方法消除了许多先前研究的局限性,这些研究从两个不同的样本中获取了老化和未老化的微观结构,只能进行定性比较。在ECTC 2018和2019年发表的最新论文中,已开发的方法用于观察微观结构在T = 125°C时效长达2000小时时,SAC305(96.5Sn-3.0Ag-0.5Cu)和SAC_Q(SAC + Bi)焊点样品中的变化最多。在当前的研究中,我们将这项工作延长了7000小时的更长的时效时间,并且我们还检查了在另一个温度(T = 100°C)下时效的微观结构变化。最后,针对最多270小时的短期老化进行了更广泛的研究,这是大多数老化引起的变化发生的时间。老化引起的微观结构变化与使用单轴拉伸试验测得的力学性能变化相关联。使用记录的图像和成像处理软件在老化过程中跟踪每个IMC颗粒的面积和直径。不出所料,对不断演变的SAC305和SAC_Q微结构的分析表明,在老化过程中,β-锡基质中大量的银和铋扩散。特别是银 3 在老化过程中,Sn颗粒会聚结,导致颗粒数量减少。观察到SAC_Q微结构中的任何铋都会迅速进入固溶体,从而导致固溶体强化。该原发发生在β-Sn树突中,但也发生在Ag中 3 树枝状晶之间的Sn富金属区域。还发现铋的存在会减慢扩散过程,使银变粗 3 锡IMC颗粒。相较于SAC305钎料合金,固溶强化结合和较低的Ag扩散率降低了SAC + Bi合金的时效效果。还研究了两种合金的机械性能退化。在测试之前,将焊料单轴试样在T = 125°C的条件下进行时效(预处理)。在每个老化温度下,考虑了几个老化时间,包括0、2、6、12和24小时。然后在高温(T = 125°C)下对老化的试样进行单轴拉伸试验。利用实测数据,确定了高温应力-应变行为随时效温度和时效时间的变化,并建立了描述机械性能随极端时效变化的模型,发现SAC_Q合金具有明显的时效性。在所有先前的老化条件下,相对于SAC305具有更好的高温机械性能。尤其是,SAC305的初始模量和极限抗拉强度在高温时效过程中经历了较大的退化,而SAC_Q的相同特性仅发生了很小的变化。机械性能的这些变化与所观察到的平均IMC粒径的增加和IMC颗粒数的减少密切相关。在老化的最初50小时内,SAC305的微观结构和材料性能下降尤为严重。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号