In this study, condensation heat transfer coefficients of R-410A were obtained in flattened tubes made from 5.0 mm inner diameter round tubes. The test range covered saturation temperature 45°C, heat flux 10 kW/ m2s, mass flux 100~400 kg/m2s and quality 0.2~0.8. Results showed the effect of aspect ratio on condensation heat transfer coefficient was dependent on the flow pattern. For annular flow, the heat transfer coefficient increased as the aspect ratio increased. For stratified flow, however, the reverse was true. The pressure drop increased as aspect ratio increased. Existing correlations adequately predicted the heat transfer coefficients and pressure drops of the flattened tubes.
机译:在该研究中,在由5.0mm内径圆形管制成的扁平管中获得R-410a的冷凝传热系数。测试范围覆盖饱和温度45°C,热通量10 kW / m2s,质量磁通100〜400 kg / m2s和质量0.2〜0.8。结果表明,纵横比对冷凝传热系数的影响取决于流动模式。对于环形流量,随着纵横比增加,传热系数增加。然而,对于分层流动,逆转是真的。随着宽高比增加,压降增加。现有相关性充分预测了扁平管的传热系数和压降。