首页> 外文会议>IEEE PES Asia-Pacific Power and Energy Engineering Conference >Methodology to differentiate type of single-phase line break fault in 10kV ungrounded distribution networks
【24h】

Methodology to differentiate type of single-phase line break fault in 10kV ungrounded distribution networks

机译:10kV未处理分配网络中单相线断裂故障区分的方法

获取原文

摘要

10kV distribution network is always a neutral point ungrounded system. Single-phase line break and grounding fault frequently occurs in 10kV distribution networks, threats the safe and stable operation of power grid and damages people's lives and properties. A methodology to differentiate type of single-phase line break fault is proposed in this paper, which uses sequence network and symmetrical components method to analyze and summarize the voltage and current variation when various single-phase line break fault occurs, then draw the voltage phasor diagram and current phasor diagram. The voltage and current variation and phasor diagrams will provide criteria for the detection and identification of single-phase line break fault in ungrounded distribution networks. Simulation results show the accuracy of the theoretical analysis in this paper.
机译:10KV分配网络始终是中性点未接地系统。 单相线断裂和接地故障经常发生在10kV配送网络中,威胁电网的安全稳定运行,损害人们的生活和性质。 本文提出了一种分辨单相线断裂故障类型的方法,它使用序列网络和对称分量方法来分析和总结各种单相线断裂故障时的电压和电流变化,然后绘制电压量量程 图和当前相位图。 电压和电流变化和量程图将提供未接地分配网络中单相线断裂故障的检测和识别的标准。 仿真结果显示了本文理论分析的准确性。