Nowadays, the deterministic load flow (DLF) methods are not adequate to meet the expectations of power system operators because of the uncertainties and variations with the consideration of renewable energy sources in power systems. Since the DLF methods use specific values instead of the stochastic values, they cannot give reliable results under the uncertainty. Therefore, a probabilistic load flow (PLF) has been included in literature as a new title to fulfill the lack of DLF methods. In this study, a comparative analysis of the Monte Carlo simulation with Latin Hypercube sampling (LHS) and the Unscented Transform (UT) methods are presented based on the results obtained from the classical Monte Carlo (CMC) simulation method. Ondokuz Mayis University (OMU) campus in Turkey is selected as a test system to implement the proposed methods and to see the results. The results show that the UT approximate method is faster and more reliable than the LHS based MC simulation method.
机译:如今,由于考虑到电力系统中可再生能源的不确定性和变化性,确定性潮流(DLF)方法不足以满足电力系统运营商的期望。由于DLF方法使用特定值而不是随机值,因此在不确定性下它们无法给出可靠的结果。因此,概率性潮流(PLF)已作为一种新的标题包含在文献中,以弥补缺乏DLF方法的不足。在这项研究中,基于从经典蒙特卡洛(CMC)模拟方法获得的结果,对采用拉丁超立方体采样(LHS)和无味变换(UT)方法的蒙特卡洛模拟进行了比较分析。选择土耳其的Ondokuz Mayis大学(OMU)校园作为测试系统,以实施建议的方法并查看结果。结果表明,与基于LHS的MC仿真方法相比,UT近似方法更快,更可靠。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号