首页> 外文会议>International Conference on Infrared, Millimeter, and Terahertz Waves >Terahertz (THz) Direct Detectors based on Superconducting HEBs with Thermal, Microwave and THz Biasing
【24h】

Terahertz (THz) Direct Detectors based on Superconducting HEBs with Thermal, Microwave and THz Biasing

机译:基于具有热,微波和太赫兹偏置的超导HEB的太赫兹(THz)直接探测器

获取原文

摘要

Terahertz (THz) direct detectors based on superconducting niobium nitride (NbN) hot electron bolometers (HEBs) with thermal, microwave (MW) and THz biasing have been studied at 0.65 THz and 4.2 K in detail. The current responsivity and noise equivalent power (NEP) have been measured and compared respectively. The detectors with the MW and THz biasing have about one order higher current responsivity than that of the thermal one. With the MW biasing, an NEP at the order of pW/√Hz is obtained by choosing the MW frequency and power appropriately.
机译:已详细研究了基于超导氮化铌(NbN)热电子辐射热计(HEB)并具有热,微波(MW)和THz偏置的太赫兹(THz)直接探测器,其探测频率为0.65 THz和4.2K。分别测量和比较了电流响应度和噪声等效功率(NEP)。具有MW和THz偏置的探测器的电流响应性比热探测器高约1倍。与MW偏压,在PW /√Hz的顺序的NEP是通过适当地选择MW频率和功率而获得。