首页> 外文会议>Biennial Baltic Electronics Conference >Performance Analysis of Low Voltage Converters for Completely Integrable Wearable Human Motion Energy Harvester
【24h】

Performance Analysis of Low Voltage Converters for Completely Integrable Wearable Human Motion Energy Harvester

机译:完全可穿戴人体运动能量采集器的低压转换器性能分析

获取原文

摘要

Electromagnetic human motion energy harvesters have shown good results previously. As the direct output of a harvester cannot be used for powering electronic devices, the paper focuses on a complete setup of rectifier, ultra-low voltage converter and a capacitor charger. The aim is to evaluate performance of off-the-shelf elements and modules for electromagnetic human motion harvester. Three commercially available converters were tested in a controlled environment and on a human separately. The best configuration obtained 4.9V on a capacitor in less than 5 minutes with peak efficiency of 22.7%, presenting a fully autonomous wearable human motion harvester as a usable voltage source.
机译:电磁人体运动能量采集器以前已经显示出良好的效果。由于收割机的直接输出不能用于为电子设备供电,因此本文重点介绍整流器,超低压转换器和电容器充电器的完整设置。目的是评估电磁人体运动采集器的现成元件和模块的性能。在受控环境中和分别在人体上对三个市售转换器进行了测试。最佳配置可在不到5分钟的时间内在电容器上获得4.9V电压,峰值效率为22.7%,这是一种完全可穿戴的人体运动采集器,可作为可用的电压源。