首页> 外文会议>IEEE International Conference on Control and Automation >Active Disturbance Rejection Control for Server Storage System Temperature Regulation*
【24h】

Active Disturbance Rejection Control for Server Storage System Temperature Regulation*

机译:服务器存储系统温度调节的主动干扰抑制控制 *

获取原文

摘要

Reducing the energy consumption for cooling in servers is a major challenge considering data center energy costs today as the power used to cool the servers has become an increasingly large component of the total power consumption. This paper presents an active disturbance rejection control based decoupling control algorithm for flash storage system in a one-unit server to simultaneously improve fan power consumption efficiency and regulate the server SSDs’ temperature to avoid downgraded performance caused by overheating. In the study, a benchmark system is established based on the Samsung Mission Peak server where the thermal characteristics and existing solutions are both systematically evaluated. Good performance of reducing throttling rate and saving fan power were attained in two case studies involving when the drive-zones are partially idle and when they are fully loaded with significant uncertain workload disturbances.
机译:考虑到当今数据中心的能源成本,减少服务器冷却中的能耗是一项重大挑战,因为用于冷却服务器的电源已成为总功耗中越来越大的组成部分。本文提出了一种基于主动干扰抑制控制的去耦控制算法,用于一台单元服务器中的闪存系统,以同时提高风扇的功耗效率和调节服务器SSD的温度,以避免由于过热而导致性能降低。在这项研究中,基于Samsung Mission Peak服务器建立了一个基准系统,在该系统中,系统地评估了热特性和现有解决方案。在两个案例研究中获得了良好的降低节流率和节省风扇功率的性能,其中涉及驱动区域部分处于闲置状态以及它们在满载时有明显的不确定的工作负载干扰。