摘要

This work introduces a flexible piezoresistive microcantilever by using polyimide (PI) and silicon oxide (SiO) as the insulation layers of titanium (Ti) strain resistors. The microcantilever is elaborately devised including the strain and piezoresistive characteristics of Ti and the film formation and patterned process of the PI. The fabricated PI/Ti/SiO microcantilever is steady and flexible with less than 3 μV@3V output voltage fluctuation in PBS buffer environment and a spring constant of 21.28 nN/μm. An aptasensor is developed through functionalizing the microcantilevers, which is able to detect ricin of 10 ng/mL concentration with good specificity. All the experiment results show that the PI/Ti/SiO microcantilever-based aptasensor enables label free and high sensitivity chemical/biological molecules detection and analysis.
机译:这项工作通过使用聚酰亚胺(PI)和氧化硅(SiO)作为钛(Ti)应变电阻器的绝缘层,引入了一种柔性的压阻微悬臂梁。精心设计了微悬臂梁,包括Ti的应变和压阻特性以及PI的成膜和构图工艺。制成的PI / Ti / SiO微悬臂梁稳定而灵活,在PBS缓冲环境中的输出电压波动小于3μV@ 3V,弹簧常数为21.28 nN /μm。通过对微悬臂梁进行功能化开发了一种适体传感器,该传感器能够以良好的特异性检测浓度为10 ng / mL的蓖麻毒蛋白。所有实验结果表明,基于PI / Ti / SiO微悬臂梁的适体传感器可实现无标记和高灵敏度的化学/生物分子检测和分析。