首页> 外文会议>Engineers' Society of Western Pennsylvania;Annual International Bridge Conference >Active Corrosion Prevention with Non-destructive Corrosion Monitoring for Suspension Bridge Main Cables
【24h】

Active Corrosion Prevention with Non-destructive Corrosion Monitoring for Suspension Bridge Main Cables

机译:悬索桥主电缆的无腐蚀腐蚀主动预防腐蚀

获取原文

摘要

Active corrosion prevention through dehumidification for main cables of suspensionbridges is experimentally analyzed on a full-scale mock-up cable. The effectiveness of thesystem is evaluated based on its ability to both reduce relative humidity to levels below 40% andsubsequently maintain low, stable relative humidity levels within the mock-up specimen exposedto variable environmental and internal cable conditions. The study uses an embedded relativehumidity and temperature monitoring system, as well as pressure and air flow monitoring toprovide a robust image of the dehumidification profile throughout the entire cable.Dehumidification proved effective in creating a dry, isolated cable interior in a number ofenvironments.
机译:通过除湿对悬架主电缆进行主动防腐 在全尺寸的模型电缆上对桥进行了实验分析。的效力 根据系统将相对湿度降低到40%以下的能力以及对系统进行评估的能力, 随后在暴露的模型样本中保持较低且稳定的相对湿度水平 适应各种环境和内部电缆状况。该研究使用了嵌入式亲戚 湿度和温度监控系统,以及压力和空气流量监控 在整个电缆上提供除湿曲线的可靠图像。 事实证明,除湿可以有效地在许多场所中形成干燥,隔离的电缆内部 环境。