首页> 外文会议>International Conference on Bioinformatics and Biomedical Engineering >Determination of the Arsenic Content in Surface Water by Silver Diethyldithiocarbamate Spectrophotometry
【24h】

Determination of the Arsenic Content in Surface Water by Silver Diethyldithiocarbamate Spectrophotometry

机译:银二乙基二硫代氨基甲酸二乙基氨基甲酸酯分光光度法测定地表水中的砷含量

获取原文

摘要

At present, arsenic in the environment has caused obviously global health problem, an effective monitoring method for measuring the content of arsenic in surface water is urgent. In this paper, the silver diethyldithiocarbamate spectrophotometric method was used to measure arsenic content in surface water. It was concluded that the related coefficient for standard curve was 0.9996, the detection limits was 0.007mg/L, the relative error was below 3.6%, the recovery efficiency of standard adding material was from 90% to 110%, which was suitable for measuring arsenic content in large quantities of surface water and wastewater. Through measuring arsenic content in the eight sections of Fen River and in the six drainage of sewage in Taiyuan, the results showed that arsenic content didn't exceed emission standards, but which was still higher than that of the environmental water.
机译:目前,环境中的砷已经引起了明显的全球健康问题,需要一种测量地表水中砷含量的有效监测方法是紧迫的。本文使用银二乙基硫代氨基甲酸盐分光光度法测定地表水中的砷含量。得出结论,标准曲线相关系数为0.9996,检测限为0.007mg / L,相对误差低于3.6%,标准加入材料的回收效率为90%至110%,适合测量大量地表水和废水中的砷含量。通过测量芬河八个部分的砷含量和太原污水六排水,结果表明,砷含量没有超过排放标准,但仍然高于环境水的含量。