A new phase deviation signal detecting method based on signal capture technology is presented to deal with the signals of double u-shaped Coriolis mass flow meter. By using the method, MCU (micro control unit) can get the whole oscillating information of the flow sensor, including normal phase deviation signal being proportional to mass flow rate and signal draft caused by noises. MCU can easily identify and delete the combined interfering signals by a simple algorithm in the software. And it can improve the anti-jamming ability and measurement accuracy. The method was implemented by using high performance MSP430F149 MCU of the Texas Instrument company. This simplified the hardware system of the signal processing board and reduced the price and energy consumption greatly.
机译:提出了一种基于信号捕获技术的新的相位偏差信号检测方法,以处理双U形科里奥利质量流量计的信号。通过使用该方法,MCU(微控制单元)可以获得流量传感器的整体振荡信息,包括正常相位偏差信号与由噪声引起的质量流量和信号径进行比例。 MCU可以通过软件中的简单算法轻松识别和删除组合的干扰信号。它可以提高抗干扰能力和测量精度。该方法是通过使用德克萨斯乐器公司的高性能MSP430F149 MCU来实现。这简化了信号处理板的硬件系统,并大大降低了价格和能量消耗。