Performance Comparison of Direct and Indirect Current Control Techniques Applied to a Sliding Mode Based Shunt Active Power Filter

机译:基于滑动模式的滑动模式分流电力滤波器的直接和间接电流控制技术的性能比较

获取原文

摘要

This paper presents a new and efficient control scheme which adopted the voltage source inverter to decrease current harmonics generated by the nonlinear load. The sliding mode control is used in the current control loop to achieve fast dynamics and a simple proportional-integral controller is adopted in the outer voltage control loop to achieve slow dynamics. The proposed scheme implements simplified control algorithms based on direct current control (DCC) and indirect current control (ICC) for designing trajectories in sliding mode control based shunt active power filter (SAPF). The performances of the DCC and ICC techniques were verified through a simulation with MATLAB. Simulation results confirm that compared to the conventional DCC scheme, the ICC scheme using sliding mode control can achieve high power factor and current harmonics elimination in SAPF.
机译:本文提出了一种新的高效控制方案,采用电压源逆变器减少非线性负载产生的电流谐波。滑动模式控制用于电流控制回路以实现快速动态,外部电压控制回路中采用简单的比例积分控制器,以实现慢动力学。该方案基于直流控制(DCC)和间接电流控制(ICC)实现简化的控制算法,用于在基于滑模控制的分流器有源电力滤波器(SAPF)中设计轨迹。通过使用MATLAB的模拟验证了DCC和ICC技术的性能。仿真结果证实,与传统的DCC方案相比,使用滑模控制的ICC方案可以实现SAPF中的高功率因数和电流谐波消除。