首页> 外文会议>IEEE International Symposium on Biomedical Imaging >AUTOMATIC MEASUREMENT OF ORBITAL VOLUME IN UNILATERAL CORONAL SYNOSTOSIS
【24h】

AUTOMATIC MEASUREMENT OF ORBITAL VOLUME IN UNILATERAL CORONAL SYNOSTOSIS

机译:单侧冠状症杂志中的轨道体积的自动测量

获取原文

摘要

Premature fusion of the coronal suture on one side of the calvaria (unilateral coronal synostosis, UCS) results in asymmetric craniofacial development and the deformation of the orbits. Often this necessitates surgery, where CT scanning is employed to obtain measures of the bony orbit. These measures are typically computed by guided procedures that require expert time. We propose a method with higher degree of automation based on finding an optimal smooth closed surface. CT scans of 17 infants with UCS are included in our experimental validation, where we compare our method to expert guided segmentations. We obtain similar measures, as well as high Dice scores, compared to the experts. The run time for the proposed approach with a prototype implementation is around 3 minutes on a standard laptop, making the method suitable for rapid evaluation of orbital volume in UCS.
机译:在Calvaria(单侧冠状梭状症,UCS)一侧的冠状缝合线的过早融合导致不对称的颅面发育和轨道的变形。通常这需要手术,其中使用CT扫描来获得骨轨道的措施。这些措施通常通过需要专家时间的指导程序来计算。我们提出了一种基于找到最佳平滑封闭表面的自动化程度较高的方法。使用UCS的17个婴儿的CT扫描包括在我们的实验验证中,在那里我们将我们的方法与专家指导分割进行比较。与专家相比,我们获得了类似的措施,以及高骰子分数。具有原型实施的提出方法的运行时间在标准笔记本电脑上大约3分钟,使得该方法适用于UCS中的轨道体积的快速评估。