摘要

The bearing capacity and stiffness of concrete-filled steel tubular (CFST) structures after long-time high temperature or emergency fire accident were decreased or even serious collapse.To obtain fire resistance of semi-rigid joints for CFST composite frames, temperature filed distribution of composite joints in fire was studied.Thermal properties and boundary conditions of steel and concrete were determined.The temperature filed model of semi-rigid joints to CFST columns with slabs was made by using ABAQUS finite element software, in considering temperature rise stage of fire modeling.The effect of composite slab, fire type and construction location were discussed and the model was verified by the test results.The temperature distribution of composite joint under three or four-side fire condition was studied by the sequentially coupled thermal analysis method.The temperature versus time curves and temperature distribution of various construction and location were analyzed.The research results will become the scientific foundation of mechanical behavior and design method of semi-rigid CFST composite frames in fire.
机译:长期高温或紧急火灾事故后,钢管混凝土结构的承载力和刚度降低甚至严重坍塌。为获得CFST复合框架半刚性节点的耐火性,温度场分布研究了复合材料火灾中的复合节点,确定了钢和混凝土的热性能和边界条件。在考虑火灾建模的升温阶段的基础上,使用ABAQUS有限元软件建立了板式CFST柱半刚性节点的温度场模型。讨论了复合板的影响,着火类型和施工位置,并通过试验结果验证了模型。通过顺序耦合热分析方法研究了三,四侧着火条件下复合缝的温度分布。分析了不同构造和位置的时间曲线和温度分布。结果将成为半硬质CFST复合材料框架在火灾中的力学行为和设计方法的科学依据。