Orientation error analysis of alt-alt photoelectric telescope

机译:ALT-ALT光电望远镜的定向误差分析

获取原文

摘要

In order to ascertain the effects of main errors of alt-alt photoelectric telescope on measurement accuracy, orientation error is analyzed. For analyzing optical, mechanical and electrical errors from measured target to telescope picture, we construct 7 coordinates such as: the earth's core coordinate, alt-alt coordinate, etc., carry through 21 times coordinate transformation, form measuring equation with 26 variables. And we utilize Monte Carlo method to calculate the orientation error, analyze the effects of errors upon pointing. The result indicates that the measuring error standard deviation of alt-alt telescope is minimum value about 10" at the zenith zone. And the deviation increases with the rotation angles of longitude and latitude axes. The model and the method not only can analyze and synthesize the main errors, but also provide a reference to the whole design.
机译:为了确定Alt-Alt光电望远镜的主要误差对测量精度的影响,分析了取向误差。为了分析从测量目标到望远镜图片的光学,机械和电误差,我们构建7个坐标,例如:地球核心坐标,Alt-Alt坐标等,携带21次坐标变换,形成具有26个变量的测量方程。我们利用Monte Carlo方法计算定向误差,分析错误时误差的影响。结果表明,Alt-Alt望远镜的测量误差标准偏差在天顶区的最小值约为10“。偏差随着经度和纬度轴的旋转角度而增加。模型和方法不仅可以分析和合成主要错误,但也提供了对整个设计的引用。