In this study, we examine a novel insight into the worst-case power noise in power integrity analysis for the core power of an ASIC. It is found that the traditional target impedance method resorting minimizing the peak impedance cannot guarantee a minimal worst-case power noise. The reason is because the worst-case power noise may not occur when the ASIC switching current is modulated at the peak impedance frequency of the power delivery network, contrary to what has been suggested in other studies. This paper discusses the fundamental mechanism behind this phenomenon. Additionally, we propose a new guideline to assess the worst-case power noise, i.e., characterizing the relationship between the power noise and the modulation frequency of the switching current. An efficient method to quickly characterize the relationship is provided, which is capable of greatly reducing the simulation time to reveal the ‘true’ worst-case power noise.
机译:在这项研究中,我们研究了对ASIC核心电力的功率完整性分析中最坏情况的最坏情况的最坏情况的洞察。结果发现,传统的目标阻抗方法借助最小化峰值阻抗不能保证最小的最坏情况噪声。原因是当在电力传送网络的峰值阻抗频率下调制ASIC开关电流时,可能不会发生最坏情况的电力噪声,这与其他研究中的建议相反。本文讨论了这种现象背后的基本机制。此外,我们提出了一种新的准则,以评估最坏情况的功率噪声,即,表征电源噪声与开关电流的调制频率之间的关系。提供了一种快速表征关系的有效方法,其能够大大减少模拟时间,以揭示“真实”最坏情况的功率噪声。