The relation between eccentricity loading and implant diameter and the reaction force versus implant diameter were analyzed. Under distributed loading, the stress was larger at the abutment/fixture interface and in the crestal bone, compared to the stress pattern under vertical loading. The amount of stress at the superstructure was similar regardless of the length, diameter, and platform shape of a fixture. Finite element models were constructed in mandible having single screw-type implant fixture connected to the premolar superstructure; this was done in order to evaluate how the length, diameter, and platform shape of a screw-type fixture influence the stress in the supporting tissue around fixtures.
机译:分析了偏心载荷与植入物直径之间的关系,以及反作用力与植入物直径之间的关系。与垂直载荷下的应力模式相比,在分布式载荷下,在基台/夹具界面以及牙槽骨中的应力更大。无论固定装置的长度,直径和平台形状如何,上部结构上的应力大小都是相似的。在下颌骨中构建有限元模型,其下颌骨具有连接到前磨牙上层结构的单螺钉型植入物固定装置;这样做是为了评估螺旋型固定装置的长度,直径和平台形状如何影响固定装置周围支撑组织中的应力。