首页> 外文会议>Chinese Control and Decision Conference >Research on concentration retrieval of the SO2/Hg0 gas mixture
【24h】

Research on concentration retrieval of the SO2/Hg0 gas mixture

机译:SO2 / HG0气体混合物浓度检索研究

获取原文

摘要

The paper researches on the concentration retrieval of the SO2/Hg0 gas mixture based on a continuum source, first using the DOAS (Differential Optical Absorption Spectroscopy) retrieves the concentration of SO2 in the total absorbance, and then removes it and retrieves the concentration of Hg0 using the way of concentration relationship curve. The result show that for the mixed gas, the retrieval error of SO2 are less than 5%, however, the error of Hg0 are more than 20%, and the less of the concentration, the greater of the error. So, the conclusion is that, when Hg0 in such a low concentration condition, the existence of SO2 will cause great interference, so must improve the algorithm to promote the retrieval precision.
机译:本文研究了基于连续源的SO2 / HG0气体混合物浓度检索,首先使用DOA(差分光学吸收光谱)在总吸收率中检索SO2的浓度,然后去除并检索HG0的浓度利用浓缩关系曲线的方式。结果表明,对于混合气体,SO2的检索误差小于5%,然而,HG0的误差大于20%,浓度越小,误差越大。所以,结论是,当HG0在这种低浓度条件下时,SO2的存在会造成极大的干扰,因此必须改善算法促进检索精度。