The high intensity pulsed electron beam of KALI-5000 system is used to develop a flash X-ray source. The KALI-5000 system is capable of generating intense relativistic electron beam (IREB) of 1 MeV, 60 kA and 100 ns when connected to impedance matched electron beam diode. This system is operated in 6 GW, 100 ns duration to produce the bremsstrahlung flash X-ray on a tantalum target of planner anode-cathode geometry. The axial and the radial dose distribution are characterized using CaSO{sub}4: Dy TLDs (thermoluminescent dosimeter) as well as using the optical densitometer to measure the dose distribution of the exposed X-ray film. The measured dose distribution by TLDs and the optical densitometer plus X-ray film matches within ± 5%.
机译:Kali-5000系统的高强度脉冲电子束用于开发闪光X射线源。当连接到阻抗匹配的电子束二极管时,Kali-5000系统能够产生1meV,60ka和100ns的强烈相对论电子束(IREB)。该系统以6 GW,100ns持续时间运行,以在规模阳极 - 阴极几何形状的钽靶上产生Bremsstrahlung闪光X射线。轴向和径向剂量分布用Caso {Sub} 4:Dy TLD(热辐发光剂量计)以及使用光学致密计来测量暴露的X射线膜的剂量分布。 TLD的测量剂量分布和光学密度计加X射线膜在±5%内匹配。