The challenging environment appearing in recent and moreover future deep offshore explorations promoted the development of linepipe steel grades with reliable sour service resistance. Severe sour conditions such as the combination of elevated production temperature, increasing pipeline pressures and high stress loads initiated by modern laying methods or introduced during service are leading to increasing corrosion demands. Steel pipelines used for the transport of media containing wet Hydrogen Sulphide (H_2S) are faced with the danger of the cracking phenomena HIC (Hydrogen Induced Cracking) and SSC (Sulphide Stress Cracking). To prove resistance to HIC and SSC, test specimens are typically tested according standardised test methods. The exposure of test specimens in a sour test solution to a H_2S pressure of 1 bar for 96 h, as described in NACE TM0284 is used to prove HIC resistance. Commonly four-point bend testing as described in EFC publication no. 16 is performed for SSC resistance testing with the appliance of a specific load, typically 80 % of the actual yield strength. Within this work HIC testing at test conditions representing higher H_2S partial pressures (up to 5 bar) and longer test durations (up to 6 months) have been performed on seamless quenched and tempered line pipe steel of grade X65 and X70 produced by VALLOUREC & MANNESMANN TUBES by plug and continuous mandrel mill process. Beside material in as delivered condition also pre-strained material was tested. SSC four-point bend testing has been performed on specimens which were strained up to 10 % of plastic strain in longitudinal direction.
机译:在最近以及将来的严峻环境中,深海近海勘探推动了具有可靠抗酸服务性的管线钢等级的发展。严酷的酸性条件(例如生产温度升高,管道压力增加和现代敷设方法引发或在服务期间引入的高应力负荷的结合)导致对腐蚀的需求增加。用于输送含湿硫化氢(H_2S)的介质的钢制管道面临着HIC(氢致裂纹)和SSC(硫化物应力裂纹)现象的危险。为了证明对HIC和SSC的抵抗力,通常根据标准化测试方法对试样进行测试。如NACE TM0284中所述,将测试样品在酸性测试溶液中暴露于1 bar的H_2S压力下96小时,以证明其耐HIC性能。通常是四点弯曲测试,如EFC出版物No.使用特定负载(通常为实际屈服强度的80%)的器具进行SSC电阻测试时,执行图16所示的测试。在这项工作中,已对VALLOUREC&MANNESMANN生产的X65和X70级无缝调质和回火管线钢进行了HIC测试,测试条件表示更高的H_2S分压(最高5 bar)和更长的测试时间(最长6个月)通过塞子和连续型芯棒轧机工艺制得的管材。除了处于交付状态的材料外,还对预应变材料进行了测试。 SSC四点弯曲测试已在试样上进行,试样在纵向上的拉伸变形高达塑性变形的10%。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号