In this paper, a calorimetric power loss measurement (CPLM) which is low cost and a simple structure using two cheap chambers. A feature of the proposed method is that the power loss of the power converter is measured from the transient state of the rise in temperature. As a result, the measurement time of the power loss using heat conduction equation formulas is reduced by 86.1% compared with a conventional method which uses the steady state of the temperature due to the power loss. In addition, another method that can reduce the measurement time is discussed. In particular, the temperature in one of two chambers is controlled to follow the temperature in another chamber for the transient stat of the rise in temperature. As a result, the measurement time of the power loss is reduced by 87.5% in compared with the conventional method. In order to confirm the validity of the proposed method for actual applications, a switching power supply is used for an objective of the power loss measurement. Moreover, the relationship among the measurement error rate, the measurement time and the chamber volume. As a result, all of the maximum errors of the measured power loss were within 10%.
机译:在本文中,量热式功率损耗测量(CPLM)成本低廉,并且使用两个便宜的腔体即可实现简单的结构。所提出的方法的特征在于,根据温度升高的瞬态来测量功率转换器的功率损耗。结果,与使用由于功率损耗引起的温度的稳态的传统方法相比,使用导热方程式的功率损耗的测量时间减少了86.1%。另外,讨论了可以减少测量时间的另一种方法。特别地,为了温度的瞬时变化,控制两个腔室之一中的温度以跟随另一个腔室中的温度。结果,与传统方法相比,功率损耗的测量时间减少了87.5%。为了确认所提出的方法在实际应用中的有效性,将开关电源用于功率损耗测量的目的。此外,测量误差率,测量时间和腔室容积之间的关系。结果,测得的功率损耗的所有最大误差均在10%以内。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号