TUBE PULLOUT TESTING EXPERIENCE

机译:管拉出测试经验

获取原文

摘要

This paper provides an overview of the use of pullout testing to determine the optimum parameters for assuring reliable tube to tubesheet joints in condensers and heat exchangers. The test is described with typical test methods, equipment and test precautions. Numerous examples of data from a variety of units, tube materials, and tubesheet materials are presented. Also included are unique tests which were performed to qualify the tube expansion procedures prior to use in nuclear facilities. These tests include mockups for pneumatic and helium leak testing, and hydrostatic testing of mockups with rolled test joints at over 600 psi. Examples will include testing with 3 roll expanders compared to 5-roll expanders in heavy gauge titanium tubes, test results with a double tubesheet arrangement, and high strength joints with thin wall titanium tubes in brass tubesheets. An example comparing the pullout forces determined with a HEI beam strip analysis to the actual pullout test data is also discussed.
机译:本文概述了使用拉出测试来确定最佳参数,以确保冷凝器和热交换器中可靠的管对管板连接。使用典型的测试方法,设备和测试预防措施对测试进行了描述。给出了来自各种单位,管材和管板材的大量数据示例。还包括独特的测试,这些测试用于在核设施中使用之前对扩管程序进行鉴定。这些测试包括用于气动和氦气泄漏测试的模型,以及在超过600 psi的压延式测试接头处进行的模型的静水压力测试。实例将包括在重型钛管中使用3辊膨胀机进行测试,而不是5辊膨胀器;在双管板布置下进行测试;在黄铜管板中使用薄壁钛管进行高强度连接。还讨论了一个示例,该示例将用HEI束带分析确定的拉拔力与实际拉拔测试数据进行比较。