Low cost, high sensitivity and stability are the key features that steer the research and development of glucose sensing. In this paper we report on a low cost metal-insulator- metal (MIM) based sensor that responds to different glucose concentrations. The unique planar Pt/CuO/Pt structure provides large electrochemically active surface area which aids glucose oxidation. The device shows sensitivity to different glucose concentrations, that span low to high blood glucose levels for typical concentrations found in human blood. The fabricated sensor exhibits the ability to detect the glucose concentration at neutral pH (i.e. pH = 7). This eliminates the dilution step needed for most of the existing nonenzymatic glucose sensors to achieve alkaline medium that is essential to perform redox reactions in the absence of glucose oxidase. Unlike the available devices, the fabricated MIM structure involves two metal electrodes in the interaction to improve the sensitivity of the device. This contribution provides new insights into design and fabrication of low cost biomedical sensors.
机译:成本低,敏感度高,稳定性是指导葡萄糖感应的研究和开发的关键特征。在本文中,我们报告了基于低成本的金属绝缘金属(MIM)的传感器,其响应不同的葡萄糖浓度。独特的平面Pt / CuO / Pt结构提供了大型电化学活性表面积,有助于葡萄糖氧化。该器件显示对不同葡萄糖浓度的敏感性,该浓度低于人类血液中发现的典型浓度的高血糖水平。制造的传感器具有检测中性pH(即pH = 7)的葡萄糖浓度的能力。这消除了大多数现有的非酶葡萄糖传感器所需的稀释步骤,以实现在没有葡萄糖氧化酶的情况下进行氧化还原反应的碱性介质。与可用的设备不同,制造的MIM结构涉及相互作用中的两个金属电极以提高器件的灵敏度。这种贡献为低成本生物医学传感器的设计和制造提供了新的见解。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号