首页> 外文会议>IEEE International Conference on Signal Processing >The calibration of the USBL transducer array for Long-range precision underwater positioning
【24h】

The calibration of the USBL transducer array for Long-range precision underwater positioning

机译:USBL换能器阵列用于远程精密水下定位的USBL换能器阵列

获取原文

摘要

this paper addresses a problem of estimating the additional phase shift between the transducers of the USBL array. The additional phase directly affects phase shift measurements due to the manufacturing technology of the transducer array, especially for the Long-range positioning system. Employing a least-squares method, the additional phase shift is considered to be determined experimentally by rotating the USBL array in an acoustic test tank. The results of the trials show that the proposed method can effectively measure the additional phase shift, and the positioning system can achieve with good accuracy after the calibration.
机译:本文解决了估计USBL阵列的换能器之间的附加相移的问题。由于换能器阵列的制造技术,附加阶段直接影响相移测量,特别是对于远程定位系统。采用最小二乘法,认为通过在声学测试箱中旋转USBL阵列来实验确定另外的相移。试验结果表明,该方法可以有效地测量额外的相移,并且定位系统可以在校准后以良好的精度实现。