首页> 外文会议>IEEE 10th International Conference on Signal Processing >The calibration of the USBL transducer array for Long-range precision underwater positioning
【24h】

The calibration of the USBL transducer array for Long-range precision underwater positioning

机译:用于远程精确水下定位的USBL传感器阵列的校准

获取原文

摘要

This paper addresses a problem of estimating the additional phase shift between the transducers of the USBL array. The additional phase directly affects phase shift measurements due to the manufacturing technology of the transducer array, especially for the Long-range positioning system. Employing a least-squares method, the additional phase shift is considered to be determined experimentally by rotating the USBL array in an acoustic test tank. The results of the trials show that the proposed method can effectively measure the additional phase shift, and the positioning system can achieve with good accuracy after the calibration.
机译:本文解决了估计USBL阵列换能器之间的附加相移的问题。由于换能器阵列的制造技术(特别是对于远程定位系统),附加相位直接影响相移测量。使用最小二乘法,可以认为通过在声学测试箱中旋转USBL阵列来实验确定额外的相移。实验结果表明,所提出的方法可以有效地测量附加的相移,并且在校准后可以实现较高的定位精度。