首页> 外文会议>International Conference on Optical Fibre Sensors >Biaxial Measurement of Optical Frequency Domain Reflectometry Using Polarization Maintaining Fiber Bragg Grating
【24h】

Biaxial Measurement of Optical Frequency Domain Reflectometry Using Polarization Maintaining Fiber Bragg Grating

机译:使用保偏光纤布拉格光栅的光频域反射仪的双轴测量

获取原文

摘要

We demonstrated the optical frequency domain reflectometry (OFDR) measurement system with all polarization maintaining fiber including fiber Bragg grating (FBG). We succeeded to obtain the slow and fast axial Bragg reflection spectra individually. We proposed the novel method to compensate the measured position miss matching between slow and fast axial Bragg reflection spectra, and confirmed the validity of the method.optical frequency domain reflectometry, polarization maintaining fiber Bragg grating
机译:我们演示了包括光纤布拉格光栅(FBG)在内的所有保偏光纤的光频域反射法(OFDR)测量系统。我们成功地分别获得了慢速和快速轴向布拉格反射光谱。我们提出了一种新颖的方法来补偿测得的慢速和快速轴向布拉格反射光谱之间的位置失配,并证实了该方法的有效性。 光学频域反射仪,保偏光纤布拉格光栅