Many times it is assumed that the material is at fault when there is a large-scale failure in a piping system. In this case, a 30-inch fusible PVC pipe, approximately 1100 feet in length failed during a pressure test. A careful analysis of the failed pipe and an assessment of the pipe properties revealed that the material was not at fault and that improper test procedures were to blame. The analysis includes fracture toughness measurements and calculations that show that the propagation of the crack was directly related to the pressure test procedures that were used including the attachment of end-caps and entrapment of air in the system.
机译:很多时候,当管道系统发生大规模故障时,都认为材料有缺陷。在这种情况下,长度约1100英尺的30英寸可熔PVC管在压力测试期间失败。对发生故障的管道进行仔细分析并评估管道性能后发现,该材料没有缺陷,应归咎于不正确的测试程序。该分析包括断裂韧性测量和计算,这些计算表明,裂纹的扩展与所使用的压力测试程序直接相关,该压力测试程序包括端盖的连接和系统中的空气截留。